HVM-K Series · High-Magnification Optical Measurement

High-Magnification Measuring Microscope

The HVM-K Series high-magnification measuring microscope combines infinity achromatic optics, scientific 4K digital imaging and an electrically lifted Z-axis with full automatic focus. A five-position nosepiece and large-travel movable stage support the inspection workflow. Choose from four X/Y travel ranges, from 200 × 100 mm to 500 × 400 mm.

  • Scientific 4K imaging
  • Electric Z-axis · Autofocus
  • 5-position nosepiece
  • Four stage sizes
Key product features

Built for Practical Dimensional Inspection

Review the HVM-K Series optical imaging, positioning, lighting, software and mechanical features before choosing a model.

Five-Position High-Magnification Optics

The Features specify 5×–100× objectives, a five-hole nosepiece and 100×–2000×+ magnification. See the separate magnification entries and configuration note below.

Large-Travel Movable Stage

Large-travel movable stage with four X/Y range options.

Electric Z Lift & Autofocus

Electric Z-axis lift with full automatic focusing.

YZ-F Measuring Software

YZ-F multi-function measuring software as listed in the Features.

Sealed Precision Glass Scale

High-precision sealed glass scale for improved dust resistance. The Setting table lists 0.1 μm scale resolution.

Imported HD Digital Camera

Imported HD digital camera with switchable image size, as described in the Features. The Setting table specifies scientific 4K digital imaging.

Granite Base & Column

Granite base and column provide the listed structural foundation for stable measurement.

One-Click Data Export

Smart software with one-click export to Excel, Word and TXT.

Choose by travel range

Compare the Four HVM-K Models

Start with the dimensions of your largest workpiece and the measurement area required for your inspection tasks.

HVM-200K

200 × 100 mm

X/Y travel

Stage: 350 × 250 mm

Glass plate: 240 × 140 mm

HVM-300K

300 × 200 mm

X/Y travel

Stage: 450 × 350 mm

Glass plate: 340 × 240 mm

HVM-400K

400 × 300 mm

X/Y travel

Stage: 550 × 450 mm

Glass plate: 440 × 340 mm

HVM-500K

500 × 400 mm

X/Y travel

Stage: 650 × 550 mm

Glass plate: 540 × 440 mm

Technical data

HVM-K Series Technical Specifications

Compare the listed specifications for all four configurations. Confirm the final configuration and acceptance conditions with the supplier before ordering.

Model-specific specifications
SpecificationHVM-200KHVM-300KHVM-400KHVM-500K
X/Y Travel (mm)200 × 100300 × 200400 × 300500 × 400
Z Travel (mm)100100100100
Overall Dimensions (mm)1300 × 650 × 16001300 × 750 × 15001350 × 880 × 15001400 × 980 × 1500
Stage Size (mm)350 × 250450 × 350550 × 450650 × 550
Glass Plate Size (mm)240 × 140340 × 240440 × 340540 × 440

Shared Technical Specifications

Shared HVM-K Series settings and source magnification entries
Magnification (Setting)50×, 100×, 200×, 500×, 1000×
Magnification (Features)100×–2000×+; configuration to be confirmed
Optical SystemInfinity achromatic optics
Imaging SystemScientific 4K digital imaging
EyepieceHigh-eyepoint wide-field plan eyepiece PL10× / 22 mm
Objective — 5×Infinity long-working-distance plan BF/DF achromatic metallographic DIC objective
Objective — 10×Infinity long-working-distance plan BF/DF achromatic metallographic DIC objective
Objective — 20×Infinity long-working-distance plan semi-apochromatic BF/DF metallographic DIC objective
Objective — 50×Infinity long-working-distance plan semi-apochromatic BF/DF metallographic objective
Objective — 100×Infinity long-working-distance plan semi-apochromatic BF/DF metallographic objective
Observation Tube30° erect-image infinity trinocular tube; interpupillary distance 50–76 mm; 100:0 / 50:50
NosepieceInternal 5-hole nosepiece
Focus SystemZ electric lift, full automatic focus
Stage3-layer mechanical stage, rod drive, speed hinge (source wording)
X/Y Accuracy (μm)1.8+L/200
Z (source label; unit not stated)3+L/200
Glass Scale Resolution (μm)0.1
Reflected Light100–240 V wide-voltage reflected-light housing; 5 W warm LED; Köhler illumination; diaphragms; oblique illumination; filter and polarizer slots
Transmitted Light100–240 V wide-voltage transmitted-light housing; 5 W warm LED
PolarizerPolarizer insert; 360° analyzer insert
Camera Accessories0.5× camera adapter; C-mount; adjustable focus
ComputerHP PC / 24-inch LCD
Available Options20× eyepiece, 100× objective, camera interface, DIC, electric joystick, full automatic focus and rotary stage

Source clarification: Features state 100×–2000×+, while Setting lists 50×, 100×, 200×, 500× and 1000×. Both entries are retained; confirm the applicable eyepiece, objective and imaging configuration. The row labeled Z lists 3+L/200 without a unit; no unit has been inferred. Confirm the definition and unit of L and test conditions. The 100× objective and automatic focus appear in both the configuration and options; confirm what is included. “Speed hinge” is retained from the source pending clarification. Illumination voltage values describe the listed light housings, not a separately stated whole-machine power specification.

Inspection use cases

Applications

The appropriate model depends on workpiece size, features to be measured and the required inspection process.

High-Magnification Observation

Use the listed objectives and imaging configuration to view small workpiece features.

Dimensional Measurement

Measure workpiece features with the large-travel stage and YZ-F software.

Illumination Selection

Use reflected or transmitted lighting and the listed polarizer/analyzer accessories as appropriate.

Measurement Reporting

Export measurement results to Excel, Word and TXT.

Frequently asked questions

HVM-K Series FAQs

Common questions to consider when selecting a manual video measuring machine.

Which models and travel ranges are listed?

HVM-200K: 200 × 100 mm; HVM-300K: 300 × 200 mm; HVM-400K: 400 × 300 mm; HVM-500K: 500 × 400 mm. All list 100 mm Z travel.

What magnification is available?

Features state 100×–2000×+, while Setting lists 50×, 100×, 200×, 500× and 1000×. Confirm the quoted optical and imaging configuration rather than assuming these describe the same setup.

Which objectives and observation tube are listed?

A five-hole nosepiece with 5×, 10×, 20×, 50× and 100× objectives is listed, together with a 30° erect-image infinity trinocular observation tube. Confirm included objectives and DIC accessories.

Which focusing and imaging systems are listed?

Electric Z-axis lift with full automatic focus and scientific 4K digital imaging. YZ-F multi-function measuring software is named in the Features.

What accuracy and resolution values are listed?

X/Y accuracy is 1.8+L/200 μm. A separate row labeled Z states 3+L/200 without a unit. Glass scale resolution is 0.1 μm. Confirm the Z unit, definition and unit of L and test conditions.

Which illumination and output functions are listed?

Reflected and transmitted 5 W warm LED lighting, polarizer and analyzer inserts are listed. Features specify one-click Excel, Word and TXT export. Confirm optional accessories and what is included.